Airfel Combi Fault Codes

Airfel Combi E1 Error, flame failure.
Airfel boiler E2 Failure – overheating.
Airfel Combi E3 Error – Burnt gas output failure.
Airfel Combi E4 Fault – Heating circuit water pressure is insufficient.
Airfel boiler E6 Error – Use water circuit NTC sensor failure
Airfel kombie7 Error – Heating water circuit NTC sensor failure.

Alarko Kombi Fault Codes

Alarko Kombi E01 Error – no flame.
Alarko Kombi E02 Error – Limit thermostat failure.
Alarko Kombi H20 Error – Water pressure failure.
Alarko Kombi E05 Error – Heating sensor failure
Alarko Kombi E06 Error – Use water circuit NTC sensor failure.
Alarko Kombi E14 Error – flue blockage failure.
Alarko Kombi E22 Error – motherboard problem.
Alarko Kombi E35 Error – Flame detection failure.

ARÇELİK Combi Fault Codes

Arcelik Kombi E01 Error – Flame failure.
Arcelik Kombi E02 Error – Limit thermostat failure.
Arcelik Kombi E03 Error – Air pressure switch failure.
Arcelik Kombi E04 Error – safety failure due to loss of flame.
Arcelik Kombi E05 Error – Installation of water failure
Arcelik Kombi E06 Error – Use water failure.
Arcelik Kombi E10 Error – Low pressure fault.
Arcelik Kombi E25-E26 Error – Possible failure of pump blockage.
Arcelik Kombi E35 Error – Flame detection error.
Arcelik Kombi E96 Error – Low voltage failure.

ARİSTON COMBI GENUS & CLAS Fault Codes

101 – overheating.
103-104 – 105-106 – 107 – recirculation or water availability. (: Reset)
110 – Heating output sensor is open or short circuit and (NTC1)
112 – Heating in return sensor open or short circuit and (NTC2)
114 – The outside sensor is open or short circuit and
116 – underfloor heating thermostat open 1P1 – 1P2 – 1P3 – recirculation or water situation
201 – DHW sensor is open or short circuit
202 – Boilers (water tank) Low sensor open or short circuit
203 – Switching the sensor is open or short circuit
204 – Solar collector sensor is open or short circuit
205 – solar collector water input sensor is open or short circuit
207 – Solar manifold overheating
208 – Solar manifold low temperatures (frost protection)
209 – Boiler excessive warming
301 – Eeprom screen error
302 – GP – GII communication error
303 – PCB internal error (can not be reset)
304 – 15 minutes more than 5 reset
305 – PCB internal error (the reset)
306-307 – PCB internal error
401 – communication error between the modem and BUS
402 – Modem error GPRS / GSM
403 – Sim card modem failure
404 – communication error between the modem and card
405-406 – The modem error
407 – Room sensor open or short circuit
501 – Flame missing
502 – The gas valve has been detected off the flame
5P3 – flame breakage during use
601-602 – Flue thermostat disabled
607 – Differential pressure switch contact open before ignition
6P1 – Differential air pressure switch delays in closing
6P2 – differential pressure switch on combustion burner
701 – Zone 2 heating output sensor error
702 – Zone 2 heating return sensor fault
703 – Zone 3 heating output sensor error
704 – Zone 3 heating return sensor error
705 – Hydraulic separator sensor error
706 – Zone 2 overheating
707 – Zone 3 overheating

ARİSTON Egis Combi Fault Codes

Ariston boiler Egis 90 Leti – Reversal of excessive heating.
Ariston boiler Egis 50-60 Ledi – Insufficient water.
Ariston boiler Egis 60-70 Ledi – Heating NTC made circuit open or short circuit.
Ariston boiler Egis 50-70 Ledi – Domestic hot water NTC made circuit open or short circuit.
Ariston boiler Egis 70 Leti – Eeprom error.
Ariston boiler Egis 80 Leti – Electronic card error.
Ariston boiler Egis 40-50 – 60 -: 70 – 80 Leds – Too much reset attempts.
Ariston boiler Egis 70 Leti – Drops Signal – Built-in electronic card problem.
Egis drip marks Ariston boiler – burner flame creation error due to the closure.
Ariston Egis Combi 50 – 60-70 LEDs – The gas valve has been detected off the flames.
Ariston Egis Combi 60 -: 70 – 80 Leds – Latest Flame.
Egis Ariston boiler flue Signal – Chimney differential pressure switch failure.

BAYMAK Combi Fault Codes

Mr Komba to Falk E01 Error – Gas supply – lock failure.
Male to Falke Combi E02 Error – Safety thermostat sensor failure.
Mr Komba to Falk E03 Error – Flue thermostat sensor / flue pressure sensor failure.
Mr. Falk Kombi to E05 Error – Heating circuit NTC sensor fault.
Mr Komba to Falk E06 Error – Use water circuit NTC sensor failure.
Mr Komba to Falk E10 Error – Low water pressure.
Mr. Falk Kombi to E25 Error – Maximum temperature warning (pump may be stuck).
Mr. Falk Kombi to E35 Error – Flame formation failure.

BAYMAK dolcevita / ECO4 Combi Fault Codes

Male to Dolcevita, Eco4 Kombi E01 Error – Basarýsýz ignition.
Male to Dolcevita, Eco4 Kombi E02 Error – Safety thermostat sensor failure.
Male to Dolcevita, Eco4 Kombi E03 Error – Waste gas thermostat / air pressure switch failure.
Male to Dolcevita, Eco4 Kombi E05 Error – outlet water sensor fault.
Male to Dolcevita, Eco4 Kombi E06 Error – Use water circuit NTC sensor failure.
Male to Dolcevita, Eco4 Kombi E10 Error – Low water pressure.
Male to Dolcevita, Eco4 Combi Error E25 – E26 – Possible failure of pump blockage.
Male to Dolcevita, Eco4 Kombi E35 Error – Flame formation failure.
Male to Dolcevita, Eco4 Kombi E96 Error – closing due to the voltage shower.

BAYMAK Brötje / LUNA3 DUOTECH Combi Fault Codes;

Male to Brötje, Luna3 Duotech Kombi E10 Error – outside ambient temperature sensor failure.
Male to Brötje, Luna3 Duotech Kombi E20 Error – Central heating circuit NTC sensor failure.
Male to Brötje, Luna3 Duotech Kombi E28 Error – Chimney NTC sensor failure.
Male to Brötje, Luna3 Duotech Kombi E50 Error – Use water circuit NTC sensor failure.
Male to Brötje, Luna3 Duotech Combi E110 Error – Safety thermostat or flue gas sensor failure.
Male to Brötje, Luna3 Duotech Combi E119 Error – Water pressure switch failure / low water pressure warning.
Male to Brötje, Luna3 Duotech Combi E125 Error – System letting water flow / circulation failure or air to the system.
Male to Brötje, Luna3 Duotech Combi E130 Error – Chimney NTC overheat warning.
Male to Brötje, Luna3 Duotech Combi E133 Error – Gas supply failure / gas insufficient warning.
Male to Brötje, Luna3 Duotech E151 Error boiler – Boiler control board failure.
Male to Brötje, Luna3 Duotech Combi E156 Error – Low or high-voltage warning.
Male to Brötje, Luna3 Duotech Combi E160 Error – Fan failure.
Male to Brötje, Luna3 Duotech Combi E193 Error – air to the system.

BAYMAK BAX Central Fault Codes

Mr Baxi boiler to E10 Error – outside ambient temperature sensor failure.
Mr Baxi boiler to E20 Error – Central heating circuit NTC sensor failure.
Mr Baxi boiler to E28 Error – Chimney NTC sensor failure.
Mr Baxi boiler to E50 Error – Use water circuit NTC sensor failure.
Mr Baxi boiler to E60 Error – Room temperature sensor failure.
Mr Baxi boiler to E62 Error – Electronic card software version failure.
Mr Baxi boiler to E88 Error – Electronic card with AVS communication failure between the control unit 77.
Mr Baxi boiler to E95 Error – AVS control unit 77 hours a failure.
Male to Baxi Boiler E110 Error – Safety thermostat or flue gas sensor failure.
Male to Baxi Boiler E119 Error – Water pressure switch failure / low water pressure warning.
Male to Baxi Boiler E125 Error – System letting water flow / circulation system failure or to air
Male to Baxi Boiler E127 Error – Anti-leyjon function is activated
Male to Baxi Boiler E130 Error – Chimney NTC overheat warning.
Male to Baxi Boiler E131 Error – 125 or 130 after discontinuation of combined electrical failures.
Male to Baxi Boiler E133 Error – Gas supply failure / gas insufficient warning.
Male to Baxi Boiler E151 Error – boiler control board failure.
Male to Baxi Boiler E155 Error – hang the maximum reset trial
Male to Baxi Boiler E156 Error – Low or high-voltage warning.
Male to Baxi Boiler E160 Error – Fan failure.
Male to Baxi Boiler E193 Error – air to the system.

BAYMAK LAMBERT 24FN Combi Fault Codes

Mr. Lambert 24FN to Combi E01 Error – Failed ignition.
Mr. Lambert 24FN to Combi E02 Error – Safety thermostat failure.
Mr. Lambert 24FN to Combi E03 Error – Waste gas thermostat, air pressure switch failure.
Mr. Lambert 24FN to Combi E05 Error – Output water NTC sensor fault.
Mr. Lambert 24FN to Combi E06 Error – Use water circuit NTC sensor failure
Mr. Lambert 24FN to Combi E10 Error – Low pressure failure.
Mr. Lambert 24FN boiler to E25 – E26 Error – Possible failure of pump blockage.
Mr. Lambert 24FN to Combi E35 Error – Flame formation failure.
Mr. Lambert 24FN to Combi E96 Error – shutdown due to voltage drop

BEKO Combi Fault Codes

Beko Combi F1 Error – Overheating safety thermostat failure.
Beko Combi F2 Error – Use water NTC sensor error.
Beko boiler F3 Error – Installation of water NTC sensor error.
Beko boiler F4 Error – Ionization error.
Beko Combi F5 Error – Failure Prosestat.
Beko boiler F6 Error – Outside sensor connection error.
Beko Combi F7 Error – Water pressure low failure.
Beko Combi CC Error – indicates that the absence of the outdoor sensor.

BOSCH Combi Fault Codes

Bosch boiler A7 Error – hot water sensor (DHW-NTC) is faulty.
Bosch boiler A8 Error – BUS communication interruption. (Check the connection cable and the thermostat.)
Bosch boiler B1 Error – Code switch is not recognized.
Bosch boiler B2 – B3 Error – Internal error.
Bosch boiler C6 Error – The fan does not work.
Bosch boiler CC Error – Outside temperature sensor is not detected.
Bosch Combi D3 Error – 8 and 9 bridges missing or external temperature limiter circuit.
Bosch boiler D5 Error – external (extern) temperature sensor is defective.
Bosch boiler E2 Error – Flow temperature NTC sensor is defective.
Bosch boiler E9 Error – safety thermostat on the heat block (STB), waste gas safety sensor or low pressure safety switch has been activated.
Bosch Combi E Error – Flame not detected.

BUDERUS boiler Fault Codes

Buderus boiler E1 Error – Chimney Drive None.
Buderus boiler E2 Error – Overheating.
Buderus boiler E3 Fault – flame does not occur.
Buderus boiler E4 Error – Came to the desired temperature.
Buderus boiler E5 Error – Potable Water 85 degrees.
Buderus boiler E6 Error – Flame not formed (Ionization Failure).
Buderus boiler E7 Error – There are clogging the chimney.
Buderus boiler E8 Error – fuse failure.
Buderus boiler E9 Error – Card fault.
Buderus boiler E0 Error – Voltage too low.

DEMİRDÖKÜM ADEN Combi Fault Codes

Demirdöküm Aden Combi 30 degrees flashing, – Installation is a fault in the water sensor.
Demirdöküm Aden Combi 40 degrees is flashing – there are errors in the use of water sensors.
Demirdöküm Aden Combi 50 degrees is flashing – there is fault on outdoor sensor.
Demirdöküm Aden Combi 60 degrees is flashing – Installations to low water pressure.
Demirdöküm Aden Combi 70 degrees is flashing – there is a bug in the flue pressure switch or sensor.
Demirdöküm Aden Combi 80 degrees is flashing – Overheating thermostat has tripped.
Demirdöküm Aden Combi 90 degrees is flashing – there is an error in the gas supply or ionization.

DemirDöküm Kalisto Combi Fault Codes

Demirdöküm Kalisto Combi F1 Failure – overheating and safety thermostat failure.
Demirdöküm Kalisto Combi F2 Fault – Domestic hot water sensor fault.
Demirdöküm Kalisto boiler F3 Failure – Installation of water sensor error.
Demirdöküm Kalisto boiler F4 Fault – Ionization error.
Demirdöküm Kalisto Combi F5 Failure – Flue gas sensor fault.
Demirdöküm Kalisto boiler F6 Failure – The outside air sensor connection error.
Demirdöküm Kalisto F7 fault boiler – Water pressure low failure.
Demirdöküm Kalisto Combi FF Failure – Ground -electronics control problem.
Demirdöküm Kalisto Combi CC Failure – Specifies whether the external temperature sensor circuit.

DemirDöküm NANOMİKS Combi Fault Codes

Demirdöküm Nanomiks Combi F0 Error – Low water pressure or no water.
Demirdöküm Nanomiks Combi F1 Error – Limit thermostat fault (excessive heat).
Demirdöküm Nanomiks Combi F2 Error – DHW temperature sensor error.
Demirdöküm Nanomiks boiler F3 Error – Installation and return water temperature sensor error.
Demirdöküm Nanomiks boiler F4 Error – Ionization error.
Demirdöküm Nanomiks Combi F5 Error – Flue temperature sensor error.
Demirdöküm Nanomiks boiler F6 Error – OTC (outdoor sensor) failure.
Demirdöküm Nanomiks Combi F8 Error – Fan speed error is outside its limits.
Demirdöküm Nanomiks Combi F9 Error – Parameter loaded error.
Demirdöküm Nanomiks Combi FF Error – Hardware / Soils / Processor error.

DemirDöküm NEVA Combi Fault Codes

Demirdöküm Neve Combi F1 Failure – overheating fault.
Demirdöküm Neve Combi F2 Error – Use water NTC sensor error.
Demirdöküm Never Kombi F3 Error – System circuit going NTC sensor error.
Demirdöküm Neve boiler F4 Error – Ionization error.
Demirdöküm Neve Combi F5 Error – Air flow switch (prosestat) error.
Demirdöküm Neve boiler F6 Error – System circuit return NTC error.
Demirdöküm Neve Combi F9 Error – Prosestat short circuit fault.
Demirdöküm Neve Combi F10 Error – Installation of water pressure circuit failure.
Demirdöküm Neve Combi F11 Error – Circulation error.
Demirdöküm Neve Combi F12 Error – Low voltage error.

NITRO DemirDöküm the Combi Fault Codes

Demirdöküm Nitro Combi F1 Failure – overheating safety thermostat failure.
Demirdöküm Nitro Combi F2 Fault – Domestic hot water circuit (DHW) temperature sensor error.
Demirdöküm Nitro Combi F3 Fault – Heating circuit (CH) temperature sensor error.
Demirdöküm Nitro Combi F4 Fault – Ionization error.
Demirdöküm Nitro Combi F5 Failure – Air flow pressure sensor error.
Demirdöküm Nitro Combi F6 Fault – Outdoor sensor connection error.
Demirdöküm Nitro F7 fault of the boiler – air flow sensor connection error.
Demirdöküm Nitro Combi F8 fault – Fan airflow error without movement.
Demirdöküm Nitro Combi F9 Fault – Wiring error.
Demirdöküm Nitro Combi F10 Fault – Heating circuit (CH) system at low pressure.
Demirdöküm Nitro Combi F11 Fault – Circulation error.
Demirdöküm Nitro Combi F12 Fault – Low voltage error.

DemirDöküm SARGON PREMIKS Combi Fault Codes

Demirdöküm Sargon Premix Combi F0 fault – Low pressure fault.
Demirdöküm Sargon Premix Combi F1 Failure – overheating safety thermostat failure.
Demirdöküm Sargon Premix Combi F2 Fault – Domestic hot water sensor fault.
Demirdöküm Sargon Premix Combi F3 Failure – Installation of water sensor error.
Demirdöküm Sargon Premix Combi F4 Fault – Ionization error.
Demirdöküm Sargon Premix Combi F5 Failure – Air flow problems.
Demirdöküm Sargon Premix Combi F6 Fault – Outside temperature sensor error.
Demirdöküm Sargon Premix Combi F7 fault – Fan feedback signal problem.
Demirdöküm Sargon Premix Combi F8 Failure – problems at the desired speed fan rotation.
Demirdöküm Sargon Premix Combi F9 fault – Fan stop error when you should stop the fan.

DemirDöküm ISOFAST Combi Fault Codes

Demirdöküm ISOFAST Combi 1 – Ionization error (Flame felt not).
Demirdöküm ISOFAST Combi 2 – Air flow failure [Air flow switch (switch) pressure felt not].
Demirdöküm ISOFAST Combi 3 – Repeated air flow error (Code 2 is repeated 3 times in 2 hours 40 minutes if ic).
Demirdöküm ISOFAST Combi 4 – Ionization error (the flame is lost during Calıs).
Demirdöküm ISOFAST Combi 5 – overheating fault.
Demirdöküm ISOFAST Combi 6 – Heating circuit (CTN2) error.
Demirdöküm ISOFAST Combi 7 – Hot water circuit (CTN1) error.
Demirdöküm ISOFAST Combi 8 – MİCROFAST circuit (CTN3) error.
Demirdöküm ISOFAST Combi 9 – Potable water system pressure failure.
Demirdöküm ISOFAST Combi 10 – Heating return (CTN5) error.
Demirdöküm ISOFAST Combi 11 – you can not get a signal from the motherboard.
Demirdöküm ISOFAST Combi 12 – you can not get a signal from the interface card.
Demirdöküm ISOFAST Combi 13 – Motherboard failure.
Demirdöküm ISOFAST Combi 14 – Heating temperature over 95 degrees Celsius.
Demirdöküm ISOFAST Combi 15 – Gas mechanism stepper motor failure.
Demirdöküm ISOFAST Combi 16 – Ionization error.
Demirdöküm ISOFAST Combi 17 – less than the voltage of 170 volts.
Demirdöküm ISOFAST Combi 18 – error in the user interface card.
Demirdöküm ISOFAST Combi 19 – Heating sensor (CTN2) is not connected.
Demirdöküm ISOFAST Combi 20 – incompatible with the motherboard interface card.
Demirdöküm ISOFAST Combi 21 – Water circulation fault.
Demirdöküm ISOFAST Combi 23 – 5 degrees Celsius temperature C / sec faster if the blaze.

DemirDöküm NEPTO Combi Fault Codes

Demirdöküm Nepto Combi F1 Failure – overheating fault.
Demirdöküm Nepto Combi F2 Fault – Domestic hot water NTC sensor error.
Demirdöküm Nepto boiler F3 Failure – Installation circuit goings NTC sensor error.
Demirdöküm Nepto boiler F4 Fault – Ionization error.
Demirdöküm Nepto Combi F5 Failure – Air flow switch (pressure switch) error.
Demirdöküm Nepto boiler F6 Fault – System circuit return NTC error.
Demirdöküm Nepto Combi F7 Fault – gas valve feedback error.
Demirdöküm Nepto Combi F8 Fault – System circuit going NTC error.
Demirdöküm Nepto Combi F9 Fault – Prosestat short circuit fault.
Demirdöküm Nepto Combi F10 Fault – System circuit water pressure failure.
Demirdöküm Nepto Combi F11 Fault – Circulation error.
Demirdöküm Nepto Combi F12 Fault – Low voltage error.

DemirDöküm ADONIS Combi Fault Codes

Demirdöküm Adonis Combi F1 Failure – overheating fault.
Demirdöküm Adonis Combi F2 Fault – Domestic hot water NTC sensor error.
Demirdöküm Adonis boiler F3 Fault – System circuit goings NTC error.
Demirdöküm Adonis boiler F4 Fault – Ionization error.
Demirdöküm Adonis Combi F5 Failure – Flue safety against the recoil.
Demirdöküm Adonis boiler F6 Fault – System circuit return NTC error.
Demirdöküm Adonis Combi F7 Fault – gas valve failure.
Demirdöküm Adonis Combi F8 Fault – System circuit NTC goings overheating error.
Demirdöküm Adonis Combi F10 Fault – System circuit water pressure failure.
Demirdöküm Adonis Combi F11 Fault – Circulation error.
Demirdöküm Adonis Combi F12 Fault – Low voltage error.
Demirdöküm Adonis Combi F13 Fault – System circuit NTC temperature difference error.

DemirDöküm ATRON Combi Fault Codes

Demirdöküm Atron Combi F1 Failure – overheating fault.
Demirdöküm Atron Combi F2 Fault – Domestic hot water NTC sensor error.
Demirdöküm Atron boiler F3 Fault – System circuit goings NTC error.
Demirdöküm Atron boiler F4 Fault – Ionization error.
Demirdöküm Atron Combi F5 Failure – Flue safety against the recoil.
Demirdöküm Atron boiler F6 Fault – System circuit return NTC error.
Demirdöküm Atron Combi F7 Fault – gas valve failure.
Demirdöküm Atron Combi F8 Fault – System circuit NTC goings overheating error.
Demirdöküm Atron Combi F10 Fault – System circuit water pressure failure.
Demirdöküm Atron Combi F11 Fault – Circulation error.
Demirdöküm Atron Combi F12 Fault – Low voltage error.
Demirdöküm Atron Combi F13 Fault – Installation circuit NTC temperature difference error.

DemirDöküm Nitromix Combi Fault Codes

Demirdöküm Nitromix Combi F00 Fault – outward NTC sensor fault (cable dislodged).
Demirdöküm Nitromix Combi F01 Fault – return NTC fault (cable dislodged).
Demirdöküm Nitromix Combi F10 Fault – NTC sensor cables outward over the creased.
Demirdöküm Nitromix Combi F11 Fault – NTC return sensor cables dislodged
Demirdöküm Nitromix Combi F20 Failure – overheating fault.
Demirdöküm Nitromix Combi F22 Fault – System water pressure is low.
Demirdöküm Nitromix Combi F23 Fault – circulation rate of the installation or very little low.
Demirdöküm Nitromix Boiler Failure F26 – F77 – gas valve failure.
Demirdöküm Nitromix Combi F27 – F28 – F29 Fault – Ionization error.
Demirdöküm Nitromix Combi F32 Fault – Faulty air pressure.
Demirdöküm Nitromix Combi F49 Fault – EBUS voltage fault.
Demirdöküm Nitromix Combi F61 – F62 – F63 – F64 Fault – motherboard failure.
Demirdöküm Nitromix Combi F65 Fault – motherboard overheating.
Demirdöküm Nitromix Combi F67 – F68 Fault – Flame detection error.
Demirdöküm Nitromix Combi F70 Fail – the connection between the motherboard and interface card failure.
Demirdöküm Nitromix Combi F71 Fault – Water flow sensor error.
Demirdöküm Nitromix Combi F73 – F74 Fault – pressure sensor error.
Demirdöküm Nitromix Combi F76 Failure – overheating fault.
The boiler Demirdöküm Nitromix Failure – User interface board error.

DemirDöküm SARGON rather than CO boiler Fault Codes

Demirdöküm Sargon Condense Combi F0 fault – Low pressure fault.
Demirdöküm Sargon Condense Combi F1 Failure – overheating safety thermostat.
Demirdöküm Sargon Condense Combi F2 Fault – Domestic hot water sensor fault.
Demirdöküm Sargon Condense Combi F3 Failure – Installation of water sensor error.
Demirdöküm Sargon Condense Combi F4 Fault – Ionization error.
Demirdöküm Sargon Condense Combi F5 Failure – Air flow switch failure.
Demirdöküm Sargon Condense Combi F6 Failure – The outside temperature sensor error.

ECA Fortius DIGITAL & Confeo Combi Fault Codes

ECA Fortius Digital / Confeo Combi E1 Error – no flame.
ECA Fortius Digital / Confeo boiler E2 Error – Wrong flame signal failure.
ECA Fortius Digital / Confeo Combi E3 Error – Excessive temperature lock (limit thermostat).
ECA Fortius Digital / Confeo Combi E4 Failure – differential pressure switch warning (short circuit).
ECA Fortius Digital / Confeo Combi E5 Error – warning differential air pressure switch (open circuit).
ECA Fortius Digital / T1 Kombi Confeo Error – Excessive heat warning (electronic limit).
ECA Fortius Digital / Confeo Kombi T2 Error – Flue gas overtemperature warning.
ECA Fortius Digital / T3 Kombi Confeo Error – Central heating temperature sensor failure.
ECA Fortius Digital / Confeo T5 Kombi Error – DHW temperature sensor failure.
ECA Fortius Digital / Confeo Combi T6 Error – Flue gas sensor fault.
ECA Fortius Digital / Confeo Combi T7 Error – Outside temperature sensor failure.
ECA Fortius Digital / Confeo boiler A1 Error – low voltage warning in the main card.
ECA Fortius Digital / Confeo Combi C1 Error – stimulating interrupted communication with the main board.
ECA Fortius Digital / Confeo Combi D1 Error – Flame circuit failure.
ECA Fortius Digital / Confeo Combi P1 Error – Low water pressure warning.
ECA Fortius Digital / Confeo boiler Y1 Error – gas valve circuit failure.

ECA Confeo Premix Combi Fault Codes

ECA Confeo Premix Combi 01 Failure – overheating fault.
ECA Confeo Premix Combi 04 Error – no flame signal.
ECA Confeo Premix Combi 05 Error – loss of flame failure.
ECA Confeo Premix Combi 06 Error – Excessive heat warning.
ECA Confeo Premix Combi 07 Error – The flue gas is locked extreme temperatures.
ECA Confeo Premix Combi 11 Error – Flame circuit failure.
ECA Confeo Premix Combi 12 Error – Closed-circuit flow sensor (NTC) failure.
ECA Confeo Premix Combi 13 Error – The flue gas sensor (NTC) failure.
ECA Confeo Premix Combi 14 Error – SKS sensor (NTC) failure.
ECA Confeo Premix Combi 16 Error – Closed-circuit return temperature sensor (NTC) failure.
ECA Confeo Premix Combi 20 Error – gas valve circuit failure.
ECA Confeo Premix Combi 24 Error – Phase failure rate.
ECA Confeo Premix Combi 32 Error – Voltage warning.
ECA Confeo Premix Combi 40 Error – Low water pressure warning.
ECA Confeo Premix Combi 42 Error – Water flow control warning.
ECA Confeo Premix Combi 99 Error – System error.

FERROLI DİVATOP Combi Fault Codes

Ferrol is Divatop A1 Error – Flame failure.
Ferrol is Divatop A2 Error – irregular flames. F
errol the Divatop A3 Error – Exchanger protection.
Ferrol is Divatop F4 Error – Flue thermostat failure.
Ferrol is Divatop F5 Error – Prosestat failure.
Ferrol is Divatop A6 Error – 4 minutes 5 times a lack of flame.
Ferrol is Divatop F8 Error – heat exchanger overheating.
Ferrol is Divatop F10 Fault – NTC heating sensor is defective.
Ferrol is Divatop F11 Fault – NTC water sensor is defective.
Ferrol is Divatop F14 Fault – NTC faulty safety sensor.
Ferrol is Divatop F34 Error – Power supply failure.
Ferrol is Divatop F35 Error – Frequency fault.
Ferrol is Divatop F37 Error – System pressure is insufficient.
Ferrol is Divatop F39 Error – External NTC is damaged.
Ferrol is Divatop F40 Error – System pressure is high.
Ferrol is Divatop F41 Error – Sensor protection is not connected.
Ferrol is Divatop F42 Error – Dual sensor readings due to differences in protection.
Ferrol is Divatop F43 Error – Exchanger protection.
Ferrol is Divatop F47 Error – Pressure sensor protection is not connected.
Ferrol is Divatop F50 Error – Moduleg not connected.

FERROLI DOMİCOMPACT Combi Fault Codes

Ferrol is Domicompact F1 Error – The burner ignition failure.
Ferrol is Domicompact F2 Error – burner flame lit. sign on.
Ferrol is Domicompact F3 Error – Safety thermostat open.
Ferrol is Domicompact F5 Error – Smoke thermostat is activated, the boiler stops working after 20 minutes.
Ferrol is Domicompact F7 Error – Return sensor is defective.
Ferrol is Domicompact F9 Error – DHW sensor is faulty.
Ferrol is Domicompact F37 Error – Low system pressure.

IMMERGAS boiler Fault Codes

Immergas Kombi E01 Error – Combustion failure.
Immergas Kombi E02 Error – Over temperature safety thermostat has switched off the circuit.
Immergas Kombi E03 Error – Flue gas thermostat is activated.
Immergas Kombi E05 Error – Heating NTC sensor is defective.
Immergas Kombi E06 Error – Use water circuit NTC sensor failure.
Immergas Kombi E07 Error – Flue gas test mode failure.
Immergas Kombi E10 Error – Insufficient water pressure.

PROTHERM LYNX Combi Fault Codes

Protherm Lynx Combi F1 Error – Error Overheat safety.
Protherm Lynx Combi F2 Error – Use Water NTC sensor failure.
Protherm Lynx Combi F3 Error – Installation Round Water NTC Sensor Failure.
Protherm Lynx Combi F4 Fault – Lack of gas or ionizing Error.
Protherm Lynx Combi F5 Error – Air Flow Error.
Protherm Lynx Combi F6 Error – System Return Water NTC Sensor Failure.
Protherm Lynx Combi F9 Error – Air Flow Switch on ignition Fault.
Protherm Lynx Combi F10 Error – Installation Water Pressure Error.
Protherm Lynx Combi F11 Error – Circulation error in the installation.
Protherm Lynx Combi F12 Error – Low Voltage Fault.

PROTHERM LEOPARD Combi Fault Codes

Leopard Protherm Kombi F0 Error – declares that reduced the water in the heater system.
Protherm Kombi Leopard F1 Error – if not visible flame occurred.
Leopard Protherm Kombi F2 Error – Heating flow sensor occurs when faulty.
Leopard Protherm Kombi F3 Error – seen in case of overheating of the device.
Leopard Protherm boiler F4 Error – Failure Ntc hot water.
Leopard Protherm Kombi F5 Error – This situation occurs when the outdoor sensor is defective.
Leopard Protherm Kombi F7 Error – your boiler Add Water bar.

Vaillant boiler Fault Codes

Vaillant boiler F.00 Error – Heating flow NTC sensor connection is broken.
Vaillant boiler F.01 Error – Heating return water NTC sensor connection is broken.
Vaillant boiler F.05 Error – Waste gas external sensor connection is broken.
Vaillant boiler F.06 Error – Waste gas inside the sensor connection is broken.
Vaillant boiler F.10 Error – Heating flow NTC sensor short circuit (<130 ° C).
Vaillant boiler F.11 Error – Heating return water NTC sensor short circuit (<130 ° C).
Vaillant boiler F.15 Error – Waste gas external sensor short circuit.
Vaillant boiler F.16 Error – Flue gas sensor short circuit inside.
Vaillant boiler F.20 Error – STB (guard thermostat) waste.
Vaillant boiler F.22 Error – Insufficient water or dry-firing.
Vaillant boiler F.27 Error – despite being covered in the report of the gas fittings flame ionization signal.
Vaillant boiler F.28 Error – stop during operation of the device avoid flame after 3 ignition attempts.
Vaillant boiler F.29 Error – flame goes out during operation.
Vaillant boiler F.36 Error – found that waste gas sensors, exhaust gas spread.
Vaillant boiler F.42 Error – Device harness shorted.
Vaillant boiler F.43 Error – disconnect the device wiring.
Vaillant boiler F.60 – F.69 error – Repair not electronic failure.

Viessmann Vitodens boiler Fault Codes

Viessmann Vitodens boiler 0B Failure – the water is low status of the heating rate.
Viessmann Vitodens boiler OCR Failure – the mains voltage is low.
Viessmann Vitodens boiler F10 / F18 Fault – interruption in the outdoor sensor or short circuit
Viessmann Vitodens boiler F30 / F38 Fault – interruption or short the temperature sensor circuit have done.
Viessmann Vitodens boiler F50 / F58 Fault – use short or temazsızlık water sensor.
Viessmann Vitodens boiler F51 / F59 Fault – outlet temperature sensor short circuit or temazsızlık.
Viessmann Vitodens boiler A9 Failure – There is no connection with the Chamber termosatat or to temazssızlık.
Viessmann Vitodens boiler E4 failure – Power supply problem exists.
Viessmann Vitodens boiler E6 failure – the water level in the boiler declined.
Viessmann Vitodens boiler B5 / E5 / F0 failure – Combi also built internal error has occurred.
Viessmann Vitodens Combi F2 failure – overheating.
Viessmann Vitodens Kombi F3 failure – began burner operation.
Viessmann Vitodens boiler F4 fault – Ionization error.
Viessmann Vitodens boiler F5 failure – Prosestat does not work.
Viessmann Vitodens boiler F7 fault – Water pressure sensor fault.
Viessmann Vitodens boiler F8 failure – closes late gas fittings.
Viessmann Vitodens Combi F9 fault – Fan fault.
Viessmann Vitodens boiler FA fault – Fan does not stop working continuously.
Viessmann Vitodens boiler FDA failure – Electronic card failure.
Viessmann Vitodens boiler Fe failure – Electronic card is not activated.

Viessmann boiler Vitopend Fault Codes

Viessmann boiler Vitopend A0 Failure – The gas pressure is low. V
iessmann Vitopend Combi E0 Malfunction – Flue gas sensor fault.
Viessmann Vitopend Combi F2 Fail – Safety thermostat failure.
Viessmann Vitopend boiler F3 Fault – Burner continues flames when working.
The Viessmann Vitopend boiler F4 fault – no flame.
Viessmann Vitopend boiler F6 Fault – Chimney NTC sensor failure.
Viessmann Vitopend Combi F30 – F38 fault – temperature NTC sensor failure.
Viessmann Vitopend Combi F51 – F59 fault – Output temperature sensor failure.
Viessmann Vitopend Combi B0 – B8 failure – flue gas NTC sensor failure.